Zearalenone(ZEN) fluorescence
quantitative rapid test card
Catalog No.: IF003A01
[Brief]
This product is used for rapid quantitative
detection of Zearalenone(ZEN) in grains and their products, feed raw materials
and some finished feed products, processing by-products, bran. It is suitable
for on-site rapid detection by various enterprises, grain depots, testing
institutions, and government regulatory departments.
[Principle]
This product is based on the principle of
competition and combined with fluorescence chromatography technology. The Zearalenone(ZEN)
in the sample competes with the ZEN-Ag coated on the NC membrane testing line
for fluorescent microsphere labeled ZEN monoclonal antibody. As the ZEN content
in the test sample increases, the amount of fluorescent microsphere antibody
complex bound to the testing line decreases, and the fluorescence intensity of
the testing line weakens accordingly. After the reaction is completed, the
content of ZEN in the sample can be detected using a matching handheld fluorescence
immunoassay analyzer.
[Application]
Grains and their products, feed raw materials
and some finished feed products, processing by-products, bran
[Specification]
20 tests/box, 50 tests/box
[Product performance]
Detection range: 0~1000μg/kg(ppb)
Detection limit: 10μg/kg(ppb)
Recovery rate: 80%~120%
[Components]
|
Components
|
Quantity
|
1
|
ZEN test card
|
20T/box
|
50T/box
|
2
|
Sample diluent
|
1bottle, 25mL/bottle
|
2bottle, 25mL/bottle
|
3
|
ID card
|
1piece
|
1piece
|
4
|
Instructions
|
1piece
|
1piece
|
[Required equipment, consumables, and reagents] (Not provided)
1. Equipment and consumables: electronic
balance, oscillator, centrifuge, pipette, and tips (20-200μL,100-1000μL, 1-5mL),
centrifuge tube (50mL, 1.5mL), disposable gloves and mask.
2. Reagent: Anhydrous ethanol (AR).
[Reagent preparation]
Sample extraction solution: Take 500mL of
anhydrous ethanol and add 500mL of pure water, mix well for usage.
[Experimental Steps]
1. Preparation before testing
a. Return the test card and sample diluent to room temperature (25℃) for at least 30 minutes.
b. Turn on the power of the fluorescence immunoassay analyzer, preheat for
10 minutes.
c. Turn on the constant temperature timer, set the incubation temperature
to 37 ℃ and the incubation time
to 8 minutes.
2. Sample preparation
Multiple point sampling is required for the test
sample, with a total sampling amount of 300-500g. After thorough mixing, the
particles can be homogenized to over 90% and pass through a 20 mesh sieve.
Extract the screened samples for testing.
a. Conventional samples
Weigh 5.0±0.05g of homogeneous sieved sample
into a 50mL centrifuge tube, add 25mL of sample extraction solution, shake for
3 minutes, and centrifuge at 4000rpm for 5 minutes. Take 50μL supernatant, add
750μL sample diluent, shake and
mix well for 10 seconds, ready for testing.
b. Bran samples (Strong water absorbing samples)
Weigh 2.5±0.025g of homogeneous sieved
sample into a 50mL centrifuge tube, add 25mL of sample extraction solution,
shake for 3 minutes, and centrifuge at 4000rpm for 5 minutes. Take 50μL
supernatant, add 750μL sample diluent,
shake and mix well for 10 seconds, ready for testing.
Note: When the concentration of the analyte in
the sample exceeds the range of the curve, the sample extraction solution can be used to dilute the extracted supernatant by 2-5 times, then take 50μL
diluted extraction solution, add 750μL sample
diluent, mix thoroughly and add the sample for testing. The final result
is obtained by multiplying dilution factor.
3. Sample testing
a. Take out the warmed test card from the aluminum foil bag, place it on a
horizontal table, and use a pipette to aspirate 70μL of the diluted sample, add
into the sample hole, insert the test card into the constant temperature
timer socket, and incubate for 8 minutes;
b. Insert the ID card of the corresponding project and batch into the fluorescence
immunoassay analyzer and read the ID card information;
c. After incubation, select the sample type (standard curve) corresponding
to the test sample, insert the test card into the fluorescence immunoassay
analyzer (see the manual of analyzer for specific operation), and click
"Test" to perform the testing.
Note: During testing, do not point the
constant temperature timer socket towards the air conditioner or fan vent.
Sample type corresponding to sample kind (standard curve)
Sample kind (standard curve)
|
Applicable sample types
|
Sample kind 1
|
Wheat, corn and other grains and their processed products
|
Sample kind 2
|
Some finished feed
|
Sample kind 3
|
Corn processing by-products and various types of meal
|
Sample kind 4
|
Bran
|
4. Result acquisition
The test results will be displayed on the screen
of the fluorescence immunoassay analyzer. You can click to print to obtain a
paper printed report, or export an electronic version of the data report
through a data cable.
[Precautions]
1. Please use the test card within its validity
period, and each card can only be used once;
2. Please use the test card immediately when
opening the aluminum foil bag packaging;
3. Different batches of test cards, sample
diluents, and ID cards should not be mixed;
4. Do not touch the white film strip at the
detection window. If touched, please discard this card to avoid affecting the
detection results;
5. Please test immediately after incubation and
try to complete the test within 2 minutes after incubation;
6. During the testing process, reagents,
instruments, etc. should be avoided from direct sunlight, fans, and air
conditioning;
7. This product is only used for screening. If a
positive result appears, it is recommended to use national standard methods for
confirmation;
8. If you encounter any problems during testing,
please contact the supplier.
9. The disposal of experimental waste shall be
carried out in accordance with national or local laws and regulations.
[Storage and shelf life]
1. This product should be stored in a dry and
dark place at 2-8 ℃, and should not be frozen.
2. The shelf life is 12 months. The batch number
and production date can be found in the outer packaging.
Shenzhen Lvshiyuan Biotechnology Co., Ltd
D Building,
National Biological Industrial Park of Marinelife, No.2 Binhai Road, Dapeng,
Shenzhen, 518120 China
Tel.
86-755-28438788 Fax
86-755-28938800
Email: info@lsybt.com Website: www.lsybt.com