Sulfamethoxydiazine (SMD) ELISA Test Kit for meat
- 2026-09-16 佚名
Sulfamethoxydiazine (SMD) ELISA Test Kit
Catalog No. LSY-10011
1. Principle
This test kit is based on the competitive enzyme immunoassay for the detection of Sulfamethoxy-
diazine in the sample. The coupling antigens is pre-coated on the micro-well stripes. The Sulfamethoxydiazine in the sample and the coupling antigens pre-coated on the micro-well stripes compete for the anti- Sulfamethoxydiazine antibodies. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value of the sample has a negative correlation with the Sulfamethoxydiazine residues concentration in the sample. This value is compared to the standard curve and Sulfamethoxydiazine concentration is subsequently obtained.
2. Technical specifications
Sensitivity: 0.4 ppb
Incubator temperature: 25℃
Incubator time: 30min~15min
Detection limit:
Tissue (high-detection-limit method) 0.4 ppb
Tissue (lower-detection-limit method)……………………………………...8 ppb
Honey (high-detection-limit method) 0.4 ppb
Honey (lower-detection-limit method)……………………………………...8 ppb
Serum, urine 1.6 ppb
Milk 8 ppb
Cross-reaction rate
Sulfamethoxydiazine (SMD) 100%
Recovery rate:
Tissue, urine, milk 85 ±25%
Honey, serum 80 ±23%
3. Components
1) Micro-well strips: 12 strips with 8 removable wells each
2) 6× standard solution (1 mL each): 0 ppb, 0.4 ppb, 0.8 ppb, 1.6 ppb, 3.2 ppb and 6.4 ppb
3) Enzyme conjugate (7 mL) red cap
4) Antibody working solution (7 mL) blue cap
5) Substrate A solution (7 mL) white cap
6) Substrate B solution (7 mL) black cap
7) Stop solution (7 mL) yellow cap
8) 20× concentrated washing buffer (40 mL) white cap
9) 5× concentrated redissolving solution (50 mL) transparent cap
4. Materials required but not provided
1) Equipments: microplate reader, printer, homogenizer, nitrogen-drying device, votex, centrifuge, measuring pipets, balance (a sensibility reciprocal of 0.01 g), incubator.
2) Micropipettors: single-channel 20-200 µL, 100-1000 µL, and multi-channel 30-300 µL;
3) Reagents: Acetonitrile (CH3CN), ethyl acetate, N-hexane, K2HPO4·2H2O, Methylene chloride
5. Storage and expiry date
Storage: store at 2-8℃, not frozen.
Expiry date: 12 months; date of production is on box.
Note: If the Vacuum package of microplate has leakage, it is still valid to use, do not affect the test result, be relax to use.
Shenzhen Lvshiyuan Biotechnology Co., Ltd
D Building, National Biological Industrial Park of Marinelife, No.2 Binhai Road, Dapeng, Shenzhen, 518120 China
Tel. 86-755-28438788/86-18165709090
Fax 86-755-28938800
Email: bella.lsybt@gmail.com info@lsybt.com
www.lsybt.com