详细信息

Sulfamethoxydiazine (SMD) ELISA Test Kit for honey

  • 2026-09-16   佚名

Sulfamethoxydiazine (SMD) ELISA Test Kit

Catalog No. LSY-10011

1. Principle

This test kit is based on the competitive enzyme immunoassay for the detection of Sulfamethoxy-

diazine in the sample. The coupling antigens is pre-coated on the micro-well stripes. The Sulfamethoxydiazine in the sample and the coupling antigens pre-coated on the micro-well stripes compete for the anti- Sulfamethoxydiazine antibodies. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value of the sample has a negative correlation with the Sulfamethoxydiazine residues concentration in the sample. This value is compared to the standard curve and Sulfamethoxydiazine concentration is subsequently obtained.

2. Technical specifications

Sensitivity:  0.4 ppb

Incubator temperature:  25℃

Incubator time:  30min~15min

Detection limit:

Tissue (high-detection-limit method) 0.4 ppb

Tissue (lower-detection-limit method)……………………………………...8 ppb

Honey (high-detection-limit method) 0.4 ppb

Honey (lower-detection-limit method)……………………………………...8 ppb

Serum, urine 1.6 ppb

Milk 8 ppb

Cross-reaction rate

Sulfamethoxydiazine (SMD) 100%

Recovery rate:

Tissue, urine, milk 85 ±25%

Honey, serum 80 ±23%

3. Components

1) Micro-well strips: 12 strips with 8 removable wells each

2) 6× standard solution (1 mL each): 0 ppb, 0.4 ppb, 0.8 ppb, 1.6 ppb, 3.2 ppb and 6.4 ppb

3) Enzyme conjugate (7 mL) red cap

4) Antibody working solution (7 mL) blue cap

5) Substrate A solution (7 mL) white cap

6) Substrate B solution (7 mL) black cap

7) Stop solution (7 mL) yellow cap

8) 20× concentrated washing buffer (40 mL) white cap

9) 5× concentrated redissolving solution (50 mL) transparent cap

4. Materials required but not provided

1) Equipments: microplate reader, printer, homogenizer, nitrogen-drying device, votex, centrifuge, measuring pipets, balance (a sensibility reciprocal of 0.01 g), incubator.

2) Micropipettors: single-channel 20-200 µL, 100-1000 µL, and multi-channel 30-300 µL;

3) Reagents: Acetonitrile (CH3CN), ethyl acetate, N-hexane, K2HPO4·2H2O, Methylene chloride 

5. Storage and expiry date

Storage:     store at 2-8℃, not frozen.

Expiry date:  12 months; date of production is on box.

Note: If the Vacuum package of microplate has leakage, it is still valid to use, do not affect the test result, be relax to use.

 

Shenzhen Lvshiyuan Biotechnology Co., Ltd

D Building, National Biological Industrial Park of Marinelife, No.2 Binhai Road, Dapeng, Shenzhen, 518120 China

Tel. 86-755-28438788/86-18165709090

Fax 86-755-28938800

Email: bella.lsybt@gmail.com   

info@lsybt.com 

      www.lsybt.co