Cefalexin ELISA Test Kit

Catalog No. LSY-10067

1. Principle

This test kit is based on the indirect competitive enzyme immunoassay for the detection of Cefalexin in samples. The coupling antigens are pre-coated on the micro-well stripes. The Cefalexin in the sample and the coupling antigens pre-coated on the micro-well stripes compete for the anti-Cefalexin antibodies. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value of the sample has a negative correlation with the Cefalexin in the sample. This value is compared to the standard curve and the Cefalexin concentration is subsequently obtained.

2. Technical specifications

Sensitivity: 0.3 ppb

Incubation Temperature: 25

Incubation Time: 30min15min

Detection limit: 

Tissue   10ppb

Egg  15ppb

Liquid milk   5ppb

Milk powder  24ppb

Cross-reaction rate:

Cefalexin  100%

Recovery rate

Tissue 10030%

Egg, liquid milk, milk powder  9030%

3. Components

1

Micro-well strips

12 strips with 8 removable

 wells each

2

6× standard solution (1mL each)

0ppb

0.3ppb

0.9ppb

2.7ppb

8.1ppb

24.3ppb

3

High concentration standard

1ml

1 ppm

4

Enzyme conjugate

7ml

red cap

5

Antibody working solution

7ml

blue cap

6

Substrate A solution

7ml

white cap

7

Substrate B solution

7ml

black cap

8

Stop solution

7ml

yellow cap

9

20× extracting buffer A

15ml

yellow cap

10

2× extracting buffer B

50ml*2

transparent cap

11

20× concentrated washing buffer

15ml

white cap

12

10× concentrated redissolving solution

10ml

black cap

4. Materials required but not provided

1) Equipments: microplate reader, printer, homogenizer, nitrogen-drying device, vortex, centrifuge, measuring pipets, balance (a sensibility reciprocal of 0.01 g), incubator.

2) Micropipettors: single-channel 20-200 µL, 100-1000 µL, and multi-channel 30300 µl ;

3) Reagents: Methanol, NaOH


5. Storage and expiry date

Storage: store at 2-8 ℃, not frozen.

Expiry date: 1 year; date of production is on box.

Note: If the Vacuum package of microplate has leakage, it is still valid to use, do not affect the test result, be relax to use.

Shenzhen Lvshiyuan Biotechnology Co., Ltd

D Building, National Biological Industrial Park of Marinelife, No.2 Binhai Road, Dapeng, Shenzhen, 518120 China

Tel. 86-755-28438788/86-18165709090    Fax 86-755-28938800

Email:  info@lsybt.com   

www.lsybt.com