Read More

Avian Influenza Virus(AIV) antibody ELISA test kit for poultry

  • Sep 09, 2026   Anon

Avian Influenza Virus(AIV) antibody ELISA test kit

(Work for Chicken, duck, goose, etc.)   

Catalog No. LSY-30028

1. Brief

This kit is used to detect Avian Influenza Virus(AIV) antibody in serum of poultry, wild birds etc., to assess antibody condition by Avian Influenza Virus(AIV) vaccine poultry and assist diagnosis of serological infected poultry.

This kit use blocking ELISA method, AIV antigen is pre-coated on enzyme micro-well strips, indirect detection of anti-AIV antibodies in serum by anti-monoclonal antibodies compete with antibodies in serum for binding sites in solid-phase vectors. When testing, add diluted serum sample, after incubation, if there is AIV virus specific antibody, it will combine with the pre-coated antigen, discard the uncombined antibody and other components with washing; then add enzyme labled anti-AIV virus monoclonal antibody, antibody in sample block the combination of monoclonal antibody and pre-coated antigen; discard the uncombined enzyme conjugate with washing; Add TMB substrate in micro-wells, the blue signal by Enzyme catalysis is in inverse proportion of antibody content in sample, use ELISA reader at 450nm wavelenth to measure the absorbance A value in reaction wells after adding stop solution to stop the reaction.

2. Reagents

Code

Item

Spec.

Code

Item

Spec.

1

AIV Ag Coated plates 96 wells

1/2 plate

6

Stop solution

15 ml

2

Enzyme Conjugate

11/22 ml

7

Negative control

2 ml

3

10XConcentrated Washing buffer  

100 ml

8

Positive control

1 ml

4

Substrate

11/22 ml

9

Adhesive Foil

2/4 pieces

5

Sample dilution

100 ml

10

Instruction

1 piece

3. Materials required but not provided

1) Micropipette: 10ul-100ul, 100ul-1000ul.

2) Disposable pipette tips.

3) Graduate: 500ml.

4) Microplate Reader: 96 wells with 450/630nm wavelength.

5) Distilled water or deionized water.

6) Bottle washer or Microplate Washer

4. Sample preparation

Take animal whole blood, make serum according to regular methods, the serum should be clear, have no hemolysis.

5. Results

Read the OD value with microplate-reader at 450nm (630nm as reference).

For the test to be valid:

Average OD value of Negative control (N) >0.4;

Calculation method:

OD value of samples/ Average OD value of Negative control = S/N value

Result judge:

S/N 0.5, Negative;

S/N < 0.5, Positive.

Specifications: 96 or 96*2 wells/kit.

Expiry date: 12 months.

Storage: Storing at 2-8℃, in the dark.


Shenzhen Lvshiyuan Biotechnology Co., Ltd 

D Building, National Biological Industrial Park of Marinelife, No.2 Binhai Road, Dapeng, Shenzhen, 518120 China

Tel. 86-755-28438788/86-18165709090

Fax 86-755-28938800

Email: info@lsybt.com  