Read More

Porcine Epidemic Diarrhea (PED) Antibody ELISA Test Kit for swine

  • Sep 09, 2026   Anon

Porcine Epidemic Diarrhea (PED) Antibody ELISA Test Kit  

Catalog No. LSY-30029


1. Usage

This kit is used to detect Porcine Epidemic Diarrhea (PED) antibody in porcine serum.

2. Principle

The GreenSpring® Porcine Epidemic Diarrhea (PED) Antibody ELISA kit uses the principle of solid-phase enzyme-linked immunosorbent assay (ELISA), and consists of a microwell reaction plate coated with high-purity PED antigen, anti-pig IgG labeled with horseradish peroxidase, and other reagents. The reaction mechanism is that the coated antigen is combined with the PED-Ab in the sample, and then combined with the enzyme-labeled anti-pig IgG antibody to form a "coated antigen+ PED-Ab+enzyme-labeled anti-pig IgG antibody" complex. Add adding Substrate, Catalytic reaction color development. The color depth is directly proportional to the amount of PED-Ab. When the color reaction of the sample is detected, the result obtained by the microplate reader exceeds the set threshold, and the result is positive, which indicates that the immune has produced antibodies or there is a natural infection.

3. The kit components 

1

PED antigen coated micro-plate

96T X 2

2

Enzyme conjugate

22ml

yellow lid

3

Sample diluent solution

50ml

transparent lid

4

PED Negative control serum

1.5ml

green lid

5

PED Positive control serum

1.5ml

red lid

6

Substrate

12ml *2

orange lid

7

Stop solution

12ml

blue lid

8

1concentrated washing buffer

50ml

white lid

9

Adhesive Foil

2 pieces


10

Instruction

1 piece


4. Material Required But not Provided

1 Microplate Reader (double-wave length: 450/630 nm).

2 Precise micropipette (single-channel 10-100ul0.5-10ulmulti-channel 30-300ul)

3 Constant temperature box or water bath box.

4 Oscillator.

5 Disposable tips (10ul, 200ul)

6 Deionized water

5. Precautions and warnings for users

       1. Read the Manual carefully before use.

       2. Do not use reagents expired, do not mix reagents from different lots.

       3. Experiment rubbish should be dealt with high pressure steam sterilization at 121 for 30 minutes, or treated with 5.0g/L sodium hypochlorite disinfectant for 30 minutes, then discard.

       4. MicroWell plate removed from the refrigerated environment should be balanced moisture to dry at room temperature, then can be opened. Put back unused MicroWell plate into dry foil bag and sealed at 4 . Unused liquid reagent should cover caps, store at 2-8 in dark with other group components.

       5. Should use Micropipettor to add sample and reagents, and often proof its accuracy.

       6. When adding washing buffer, should be full but no overflow, avoid appearing free enzyme at mouth of well or cross pollution between wells.

       7. Stop solution is corrosive, use large amount of water to wash immediately when touch the skin or clothes.


Specifications: 96*2 wells/kit(2plates).

Expiry date: 12 months.

Storage: Storing at 2-8℃, in the dark, No frozen.

Manufacture date and Lot number please see outer box.

For veterinary diagnosis only

Shenzhen Lvshiyuan Biotechnology Co., Ltd 

D Building, National Biological Industrial Park of Marinelife, No.2 Binhai Road, Dapeng, Shenzhen, 518120 China

Tel. 86-755-28438788/86-18165709090

Fax 86-755-28938800

Email: info@lsybt.com      

www.lsybt.com