Read More

Swine Transmissible Gastroenteritis (TGE) Antibody ELISA kit for pig

  • Sep 10, 2026   Anon

Swine Transmissible Gastroenteritis (TGE) Antibody ELISA kit 

Catalog No. LSY-30030

1. Usage

The Swine Transmissible Gastroenteritis (TGE) Antibody ELISA test kit is used for the detection of the Transmissible Gastroenteritis (TGE) antibody in swine serum; assessment the immunity conditions against TGE virus, serological diagnosis of pig infection in the pig farms and investigation of the epidemiology of the TGE virus.

2. Principle

This kit use indirect ELISA method, Genetically engineered TGE antigen is pre-coated on enzyme micro-well strips. When testing, add diluted serum sample, after incubation, if there is TGE specific antibody, it will combine with the pre-coated antigen, discard the uncombined antibody and other components with washing; then add enzyme labled anti-TGE antibody, combine with the antigen-antibody complex on the plate; discard the uncombined enzyme conjugate with washing; Add TMB substrate in micro-wells, blue product formed enzymatically, after adding stop solution to stop the reaction, use ELISA reader at 450nm wavelength to measure the absorbance A value in reaction wells .

3. The kit components 

Code

Item

Spec.

Code

Item

Spec.

1

TGE-Ag Coated plates

96 wells

2 plates

7

Stop solution

12 ml

2

Enzyme Conjugate

24 ml

8

Negative control

1.5 ml

3

10X Concentrated washing buffer  

100 ml

9

Positive control

1.5 ml

4

Substrate A

12 ml

10

Serum dilution plate

2 pieces

5

Substrate B

12 ml

11

Adhesive Foil

4 pieces

6

Sample diluent

100 ml


Instruction sheet

1 piece

4. Materials Required But Not Provided

1) Micropipettors: 0.5μL~10μL10μL~100μL100μL~1000μL

2) Disposable pipette tips

3) Measuring cylinder: 500 ml

4) 96 wells microplate reader

5) Distilled water or deionied water

6) Bottle or microplate washing machine 

5. Results

Set zero at blank control, read the OD value with ELISA reader at 450nm(630nm as reference)

For the assay to be valid:

OD Value of Negative control (N)< 0.1, meanwhile OD value of Positive control (P)0.4.

If OD value of sample 0.20+ average OD value of Negative control(N), it is Positive;

If OD value of sample 0.20+ average OD value of Negative control(N), it is Negative.

Calculate it as 0.05 if the average OD value of Negative control(N) less than 0.05

Expiry date: 12 months.

Storage: Store at 2~8, in the dark.

Production Date: On outer-packing of the test kit.

Shenzhen Lvshiyuan Biotechnology Co., Ltd 

D Building, National Biological Industrial Park of Marinelife, No.2 Binhai Road, Dapeng, Shenzhen, 518120 China

Tel. 86-755-28438788/86-18165709090  Fax 86-755-28938800

Email: info@lsybt.com  

www.lsybt.com